Selected:

6 parameters ICU portable patient monitor

GHS 12,919.50
Super Deals

6 parameters ICU portable patient monitor

GHS 12,919.50
Super Deals

multi-parameter 6 parameters Cardiac ICU portable patient monitor

Add to Wishlist
Add to Wishlist
Estimated Delivery Date: March 29, 2024 - April 5, 2024

Description

Product Description
 

Sinohero AcuitSign M5 portable Modular Patient Monitor

● Introductions:
AcuitSign M5 is a High Acuity 12.1″ Multi-Parameter Modular Patient Monitor, which can offer multiple parameter modules to choose from, adapting to the flexible parameter combination requirements in high acuity applications. With its plug-and-play modules, our modular patient monitor is able to monitor a wide range of parameters simultaneously, such as ECG, RESP, SpO2, NIBP, 2 TEMP, IBP, EtCO2, BIS, EEG, CO, ICG, AG etc adapting from critical cares to anesthesia monitoring. It also integrates parameter measuring module call EMS with full touch display and recorder in one device to form a compact and portable device. At the same time, with its built-in replaceable battery delivering anuninterrupted monitoring during patient transfer.

Application:

It suitable for bedside, operation room, ICU, CCU etc.

● Features: AcuitSign M5 (12.1″TFT) Module Patient Monitor 12.1″ High resolution LCD display with Full-touch screen option Unique multi-parameter module ensure seamless information workflow Advanced modular design with power networking High-End parameters including: BIS, CO, EtCO2, AG/Multi-gas, ICG, IBP, etc. Powerful data review with 168 hours of graphic & numeric data review Up to 12 channels of waveforms with various screen layout Ultra quite design suitable for night-time operation Main Unit Mainunit Display: 12.1″ TFT-LCD Display for M5 Touch Screen: Full-touch screen option for M5 Other Option Modules BIS Module, CO Module, AG/Multi-gas Module, ICG Module, IBP Module, TEMP Module, Mainstream EtCO2 Module, Sidestream EtCO2 Module, Microstream EtCO2 Module, Nellcor SpO2 Module, Masimo SpO2 Module Technical Specifications of AcuitSign M5 Standard Configuration: Mainunit:12.1″TFT-LCD display,4 Standard module slot,1Additional module rack Slot(for EMS all-in-one module), 1 RJ45 internet socket,1 Defibrillation Outpit,1 Nurse Call socket,1VGA port,4 USB1.1 port,1 Auxiliary Module Rack connector Option of AcuitSign M5: EMS module: 8 Kinds of option Option Module: Sidesteam CO2 module, Microstream CO2 module, Mainstream CO2 module, AG module, ICG module, IBP module, Temp module, , Nellcor SpO2 module, Masimo SpO2 module, BIS module, CO module SD Memory Module Rack: Auxiliary Module Rack Navigating: USB compatible mouse and keyboard. Printing: 3 Channel Thermal Recorder Mounting: Rolling stand, Wall mount Battery: 11.1V/4.0AH Rechargeable Lithium Battery (max 2 pcs), Other options: External Display, Wireless Lan, Extensive Memory card, Analog Output (ECG or IBP), Full Touch Screen

Performance: Display: -12.1″ Anti-dazzling Color TFT-LCD -Resolution: 800×600 pixels Battery (Option): -Type: Rechargeable Lithium battery,11.1V/4.0AH -Operating time under the normal use and full charge:≧150minutes -(2 batteries for 300 minutes) Recorder (Option): -Method: Thermal dot array -Paper width:50mm(1.97 in) -Paper length:15m -Paper Speed:12.5/25/50(mm/sec) -Traces: Maximum 3 tracks -Recording way: Real-time recording, Periodic recording, Alarm recording Alarm: -Level: Low, medium and high -Indication: Auditory and visual -Patient Physiological Alarm Light color: Yellow & Red: -Equipment Technical Alarm Light color: Blue -Supports Pitch Tone and multi-level volume; -Supports custom arrhythmia tone Input device: -Touch screen (Option). -knob: standard config -Mouse input: Support -Keyboard input: Support System Output & Extensible Interfaces: -Ethernet Network:1 Standard RJ45 socket -Defibrillation Output:1 RJ11 socket -Nurse Call:1 BNC socket -Video Output:1VGA port -USB1.1 port:4 -Auxiliary Module Rack connector.1 -SD memory card:2G (option) -Analog Output(ECG or IBP):Option Trend & Reviewing: -Trend:168 hours -NIBP measurement reviewing:1000 groups -ARR event:128 groups of ARR event and the associated waveform -Alarm events:128 groups of parameter alarm events and associated parameter -Waveform at the alarm moment Holographic waveform: The storage time depends on the stored waveforms and the quantity of them. Environment: -Operating temperature:0~+40℃ -Storage temperature:-20℃ to +50℃ -Operating humisity:15%to85%(non condensing) -Storage humidity :10% to 93%(non condensing) -Operating atmospheric pressure:860hPa to 1060hPa -Storage atmospheric pressure:500hPa to 1060hPa Safety: -IEC60601-1 Approved, CE marking according to MDD93/42/EEC ECG: -Lead Mode:3-leads ECG input 5-leads ECG input 12-leads ECG input -Lead selection:Ⅰ,Ⅱ,Ⅲ Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V- Ⅰ,Ⅱ,Ⅲ, aVR,aVL,aVF,V1~V6(option) -Gain: 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1), 20mm/mV(×2), 40mm/mV(×4),Auto -RR: Monitor mode≧105dB Surgery mode≦105dB Diagnostic mode≧90dB -Frequency response(-3d B): Monitor mode 0.5~40Hz Surgery mode 1~25Hz Diagnostic mode 0.05~150Hz -input impedance: ≧5.0Mohm -ECG signal range:±10.0mV -Electrode offset potential: ±500mV -Patient Leakage Current:<10uA -Standardizing signal:1mV±5% -Baseline recovery:<5s after Defibrillation.(Mon or Surg mode) -Indication of electrode separation: Every electrode(exclusive of RL) -Protection: Breakdown Voltage 4000AVC 50/60Hz;defibrillator proof -Sweep speed:12.5mm/s,25mm/s,50mm/s
HR: -Range: Adult 10~300bpm Pediatric & Neonate:10~350bpm -Refreshing time:≦50 bpm per 2 pulses 50~120bpm per 4 pulses ≧120bpm per 6 pulses -Resolution: 1bpm -Accuracy:±1% or ±1bpm,whichever is greater ST segment: -Measurement range:-2.0mV~2.0mV -Accuracy:-0.8mV~0.8mV: ±0.02mV or ±10% whichever is greater Over ±0.8mV:unspecified -Resolution:0.01mV RESP : -Method: Thoracic impedance -Lead Selected from:Ⅰ(RA-LA)orⅡ(RA-LL);Default:Ⅰ -Gain:×0.25, ×1, ×2, ×4 -Bandwidth:0.25Hz to 2.0Hz (-3dB) -Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s -Measurement Range:0~150 rpm -Resolution: 1rpm -Accuracy: ±2rpm or 2% whichever is greater -Delay of Apnea Alarm:10s,15s,25s,30s,35s,40s,45s,50s,55s,60s NIBP : -Way of measurement: Automatic oscillometry -Range of measurement: Adult: SYS 30~270mmHg DIA 10~220mmHg MAP 20~235mmHg Child: SYS 30~235mmHg DIA 10~220mmHg MAP 20~225mmHg Neonate: SYS 30~135mmHg DIA 10~100mmHg MAP 20~125mmHg -Cuff pressure range:0~300mmHg -Resolution:1mmHg -Pressure Accuracy: Static:±2% or ±3mmHg,whichecer is greater Clinical: ±5mmHg average error Standard deviation:≦8mmHg -Unit: mmHg, kPa -Measurement mode: Manual, Auto, STAT -Intervals for AUTO measurement time:1,2,3,4,5,10,15,30,60,90 minutes; 2,4,8,12hours -STAT mode cycle time: keep 5 minutes, at 5 seconds interval. -Overpressure Protection: Hardware and software double protections -Pulse rate range:40~240bpm Standard SpO2(Digital): -Measurement Range:0~100% -Resolution:1% -Accuracy: At70~100%,±2% At0~69%,unspecified PR: -Measurement Range:25~255bpm -Resolution:1bpm -Accuracy: ±1% or ±1bpm,whichever is greater Nellcor-SpO2: -Measurement Range:0~100% -Resolution:1% -Accuracy:At70~100%:±2%(Adult) At70~100%:±3%(Neonate) At70~100%:±2%(Low Perfusion) At0~69%,unspecified PR: -Measurement Range:20~300bpm -Resolution:1bpm -Accuracy: 20bpm to 250bpm: ±3bpm 251bpm to 300bpm: unspecified Masimo-SpO2: -Measurement Range:0% to 100% -Resolution:1% -Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion conditions) 70% to 100%:±3%(neonate,non-motion conditions) 70% to 100%:±3%(motion conditions) 0% to 69%, unspecified -Average time:2-4s,4-6s,8s,10s,12s,14s,16s PR: -Measurement Range:25bpm to 240bpm -Accuracy: ±3bpm(non-motion conditions) ±5bpm(motion conditions) -Resolution:1bpm TEMP : -Max Channel: 8 -Measurement way: Thermal resistance way -Measurement Range: 0.0℃~50.0℃(32℉~122℉) -Accuracy: ±0.1℃ or ±1℉(exclusive of probe) -Resolution: 0.1℃ or 1℉ -Unit: Celsius(℃),Fahrenheit(℉) -Connecting cable: Compatible with YSI-400 serial IBP : – Max Channel: 8 – Measurement way: Directly invasive pressure measurement – Sensitivity of transducer: 5uV/V/mmHg, ±2% – Impedance of transducer: 300 to 3000Ω – Measurement Range: -50~+350mmHg – Resolution: 1mmHg – Unit: mmHg, kpa, H2O – Accuracy: Static: ±1mmHg or ±2%, whichever is grater(exclusive of transducer) ±4mmHg or ±4%, whichever is grater(inclusion of transducer) Dynamic: ±4mmHg or 4%, whichever is grater Transducer sites: Arterial Pressure (ART) Pulmonary Artery Pressure (PA) Left Atrium Pressure (LAP) Right Atrium Pressure (RAP) Central Venous Pressure (CVP) Intracranial Pressure (ICP) P1/P2 -Selection of measurement range: ART:0~+350mmHg PA:-10~+120mmHg CVP/RAP/LAP/ICP:-10~+40mmHg P1/P2:-50~+350mmHg EtCO2(Sidestream): -Measure method: Infrared spectrum -Measure Range: 0.0~13.1%(0~99.6mmHg) -Resolution: 1mmHg -Unit: %,mmHg,kpa -Accuracy: 0% to 4.9%,±0.3%(±2.0mmHg) 5.0%to 13.1%,<±10%of the reading -Measurement range of awRR:3~150rpm -Calibration: Offset calibration:auto,manual,Gain calibration EtCO2(Mainstream): -Measure method: Infrared spectrum -Warm up time: Capnogram displayed in less than 15 seconds,At an ambient Temperature of 25℃, full specifications within 2 minutes. -Measure Range: 0.0~19.7%(0~150mmHg) -Resolution: 1mmHg -Rise time(10l/min):≦60ms -Unit: %,mmHg,kpa -CO2 Accuracy:0-40mmHg, ±2mmHg 41-70mmHg, ±5% of reading 71-100mmHg, ±8% of reading 101-150mmHg, ±10% of reading (at 760 mmHg,ambient temperature of 25℃) -awRR measurement range:0~150rpm -awRR measurement Accuracy: ±1rpm EtCO2(Microstream): -Measure method: Infrared spectrum -Warm up time: Capnogram displayed in less than 20 seconds, At an ambient Temperature of 25℃,full specifications within 2 minutes. -Measure Range: 0.0-19.7%(0-150mmHg) -Resolution: 1mmHg -Unit: %,mmHg,kpa -CO2 Accuracy: 0-40mmHg, ±2mmHg 41-70mmHg, ±5% of reading 71-100mmHg, ±8% of reading 101-150mmHg, ±10% of reading (At 760 mmHg,ambient temperature of 25℃) (When RR>80 rpm, all the rang is ±12% of reading) CO2 response time: <3S -awRR measurement range:2~150rpm -awRR measurement Accuracy: ±1rpm -Sample Flow Rate:50ml/min ±10ml/min Multi Gas: -Measure method: Infrared spectrum -Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,NEF,SEV,DES) -Resolution:1% -Unit:% -Calibration: Room air calibration automatically when changing airway Adapter (<5 sec) -Warm-up time:<10S,full accuracy within 1min -Measurement and alarm range of AG – Gas Range Accuracy CO2 0-10% ±(0.3% ABS+4%REL) N2O 0-100% ±(2% ABS+8%REL) O2 10-100% ±(2% ABS+2%REL) HAL,ISO,ENF 0-5% ±(0.15% ABS+10%REL) SEV 0-8% ±(0.15% ABS+10%REL) DES 0-18% ±(0.15% ABS+10%REL) -awRR measurement range: 0~150rpm -awRR measurement Accuracy: ±1rpm -Rise time(flowing speed 10I/min)CO2≦90ms O2≦300ms N2O≦300ms Hal,Iso,Enf,Sev,Des≦300ms -Total system response time :<1seconds Noninvasive Cardio Output (ICG): Method: Measurement of thoracic electrical bioimpedanc -Measurement Range:HR:40~250bpm SV:5~250ml SI:5~125ml/m2 C.O.:1.4~15L/mm TFC:15~143KΩ -Accuracy: HR±2bpm SV: unspecified C.O unspecified -Alarm range: C.L.:0.0L/min/m2 to 15.0 L/min/m2 continuously adjustable TFC: 10/KΩ to 150/kΩ continuously adjustable. BIS: -More detail please refer to BIS Specification CO: -More detail please refer to CO Specification Power supply: -Power Voltage: AC 100-240V 50/60Hz -Power Input: ≦150VA -Input Current:1.7~0.8V -Safety class: Category I

Reviews

There are no reviews yet.

Be the first to review “6 parameters ICU portable patient monitor”

Your email address will not be published. Required fields are marked *

Quick Navigation
Select your currency
$
GHS
×
×

Cart