Selected:

Patient Monitors 12 Inches

GHS 5,288.28
Super Deals

Patient Monitors 12 Inches

GHS 5,288.28
Super Deals

Patient Monitors 12 Inches Icu Superstar Patient Monitors Monitoring Equipment

Add to Wishlist
Add to Wishlist
Estimated Delivery Date: April 25, 2024 - May 2, 2024

Description

Quick Details
Place of Origin:Jiangsu, China
Brand Name:Superstar
Model Number:H8
Power Source:Electric
Warranty:1 Year
After-sale Service:Online technical support
Material:Acrylic, metal, Plastic, Steel
Shelf Life:1years
Quality Certification:ce
Instrument classification:Class II
Safety standard:GB15979-2002
Product name:patient monitor
Power Supply:50/60Hz
Feature:Durable
Certificate:CE ISO
Function:Surgery Medical
Usage:Medical Health Services
Packing:carton
Product name H8 Multi Parameter Monitor
ECG Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s 2 RESPARATION Method Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
NIBP Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm
Alarm Typ: SYS, DIA, MEAN4.SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50℃
Resolution: 0.1 ℃
Accuracy: ±0.1 ℃I.6 7 IBP
Label:ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART : 0 ~ 300 mmHg PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP : -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg Press Sensor Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy: +-2% or +- 1mmHg, which great
Actualization interval: about 1 Sec. 7.EtCO2
Method: Sidestream or Mainstream
Measuring Range: 0~150mmHg
Resolution:
0~69 mmHg, 0.1 mmHg
70~150 mmHg, 0.25 mmHg
Accuracy:
0~40 mm Hg ±2 mm Hg
41~70 mm Hg ±5%
71~100 mm Hg ±8%
101~150 mm Hg ±10%
AwRR Range: 2~150 rpm
AwRR Accuracy: ±1BPM
Apnea Alarm: Yes

Reviews

There are no reviews yet.

Be the first to review “Patient Monitors 12 Inches”

Your email address will not be published. Required fields are marked *