Selected:

Mindray Bc6200 Hematology Analyzer

GHS 138,941.77
Super Deals

Mindray Bc6200 Hematology Analyzer

GHS 138,941.77
Super Deals

Add to Wishlist
Add to Wishlist
Estimated Delivery Date: June 7, 2024 - June 14, 2024

Description

Product Specification

Automation Fully Automatic
Instrument Name Haematology Analyzer
Brand Mindray
Differential Type 3-Part
Usage/Application Hospital
Number Of Chambers 1
Parameters Blood Alcohol Content
Number Of Parameters HCT
Model Name/Number BC6200
User Input Touch
Display Digital
Sample Mode Whole Blood
Chamber Type Double Chamber
Frequency 50Hz
Weight 21 Kg
Is It Portable Portable
Dimension 360 x 470 x 430mm (L x W x H)
Voltage 240V

Product Description

Description:
At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/RET/body fluid results generated in a small-footprint system, among others, all within limited budget. Mindray BC-6200 fulfills all these clinical requirements and exceeds your expectations!

SF Cube Technology 

With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells (6 parts, including  Immature Granulocyte), which is the key to revealing more abnormal cells.

NRBC result in every CBC 

In WNB scattergram, BC-6200 provides NRBC, Basophils and WBC-N* results. The exact number of basophils and NRBCs (if any) will be counted in this independent channel without extra reagent or cost.

NLR parameter in each CBC+DIFF
 

  •  Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample.
  •  In laboratory medicine, NLR is used as a marker of subclinical inflammation.
  •  According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients.

By utilizing the new fluorescent dye, the reticulocytes and platelets are more specifically stained with stronger fluorescent signal, that brings more Accurate–reliable reticulocyte and platelet results.

Automatic Rerun & ReflexShould the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check

Less testing timeBC-6200 can load up to 50 samples at a time and offer a throughput of up to 110 tests per hour.

Low sample volume

BC-6200 requires less sample volume as well as reagent consumption. For a CBC+DIFF test with NRBC result, BC-6200 only requires 80μL of whole blood and 35 μL of capillary blood.

At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/RET/body fluid results generated in a small-footprint system, among others, all within limited budget. Mindray BC-6200 fulfills all these clinical requirements and exceeds your expectations!

glp19-s3
  • SF Cube Technology

    With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells (6 parts, including  Immature Granulocyte), which is the key to revealing more abnormal cells.

    glp18-s2-1
  • NRBC result in every CBC

    In WNB scattergram, BC-6200 provides NRBC, Basophils and WBC-N* results. The exact number of basophils and NRBCs (if any) will be counted in this independent channel without extra reagent or cost.

    glp18-s2-2
  • NLR parameter in each CBC+DIFF

    · Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample.

    · In laboratory medicine, NLR is used as a marker of subclinical inflammation.

    · According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients.

    glp18-s2-3
  • More accurate RET and PLT-O result

    By utilizing the new fluorescent dye, the reticulocytes and platelets are more specifically stained with stronger fluorescent signal, that brings more Accurate–reliable reticulocyte and platelet results.

    glp19-s2-4
  • Automatic Rerun & Reflex

    Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check

    glp19-s2-5
  • Less testing time

    BC-6200 can load up to 50 samples at a time and offer a throughput of up to 110 tests per hour.

    glp18-s2-5
  • Low sample volume

    BC-6200 requires less sample volume as well as reagent consumption. For a CBC+DIFF test with NRBC result, BC-6200 only requires 80μL of whole blood and 35 μL of capillary blood.

Reviews

There are no reviews yet.

Be the first to review “Mindray Bc6200 Hematology Analyzer”

Your email address will not be published. Required fields are marked *