  • Brand Name: Sinohero
  • Origin: China
  • Item Type: Electrocardioscanner
  • Material: ABS
  • Model Number: TS15
  • Model: TS15 Multi-Parameters ICU Module Vital Signs Patient Monitor
  • Parameters: ECG SPO2 NIBP TEMP ETCO2 IBP
  • ECG waveform: Arrhythmia and ST-segment analysis
  • NIBP: Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
  • Display: 15.6” Touch Screen
 
 
 

Introduction:

TS15 is a Module monitor is applicable for clinical monitoring in operating room,postoperative observation room,Icu/ccu ward, emergency room, etc.of adult, pediatric and neonate.The patient’s vital parameters (ELCG (including ST-sement measurement and arrhythmia analysis),RESP,SpoO,.PR, NIBP,TEMP, IBPand Co, etc.) can be monitored.Monitored information can be displayed,reviewed, printed and stored.



Feature

15.6″ high-definition touch screen design,easy and convenient to operate,elegant and concise in appearance.
Independent physiological and technical alarm function,convenientfor medical staff to quickly know patient’s condition.
Luminous””ON / OFF” button design, convenient to operate at night.
Modular design:the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets themonitoring requirements of different departments on different parameters.
Support dynamic hot-plugging parameter module: no need to restart the device,plug-and-play,change the monitoring parameters at anytime as clinical requirements.
Adopt high-performance processor, stable, relliable and fast to process information.
Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched , meets the requirements ofdifferent departments.
Abundant analysis functions: 23 arrhythmla,full-lead ST-segment and pacing analysis, multiple calculation functions [such as calculationof drug concentration , titration table, hemodynamics, ventilation, oxygenation, renal function, etc.).
With the functions of waveform freezing, holographic waveform storage and review.
Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage.
With HDMl expansion interface, the display screen can be connected according to clinical requirements.
Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring.
Fanless design, ensures no noise and low power consumption during warking.
3-channel built-in recorder used to print real-time waveform is optional.
Connectto Central Monitoring System developed by our company by WwiFi / Wwired,.convenient to transmit patient’sreal-time data.
Standby mode, be applied to lCU, avoids affecting patient’ s rest, one-button switching,reduces the workload of medical staff, Performance


Performance:

ECG
Lead type:
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V
12-lead: I, II, III, aVR, aVL, aVF, V1,V2,V3,V4,V5,V6

Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV
Scan speed: 5 mm/s, 25 mm/s, 50 mm/s

HR
Measurement and alarm range:
Adult: 15 ~ 300 bpm
Pediatric/neonate: 15 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1 % or ± 1 bpm, whichever is greater
ST-segment detection
Measurement and alarm range: – 2.0 mV ~ + 2.0 mV
Accuracy: – 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater
Other range: unspecified
Arrhythmia analysis: 23 kinds
Pacemaker: yes

RESP
Measurement mode: R-F(RA-LL) impedance
Respiration rate:
Measurement range:
Adult: 0 rpm ~ 120 rpm
Pediatric/neonate: 0 rpm ~ 150 rpm
Resolution: 1 rpm
Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater; 0 ~ 6 rpm, unspecified
Apnea alarm:10 ~ 120 s, not alarm
Scan speed: 25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s

NIBP
Measurement mode: Oscillometry
Working mode: Manual/AUTO/Continuous
Measurement interval in AUTO mode: 1min, 2 min, 5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h
Measurementperiod in Continuous mode: 5 minutes
Measurement and alarm range: 10~ 270 mmHg
Resolution: 1mmHg
Cuff pressure accuracy:± 3 mmHg
Measurement accuracy:
Maximal mean deviation: ± 5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297 ± 3 mmHg
Pediatric mode: 240 ± 3 mmHg
Neonatal mode: 147 ± 3 mmHg

CONTEC SpO2
Measurement range: 0% ~ 100 %
Resolution: 1%
Accuracy: 70% ~ 100 %, ± 2 %;
0 % ~ 69 %, unspecified

PR
Measurement and alarm range: 25 ~ 250 bpm
Accuracy: ± 2 bpm or ± 2 %, whichever is greater
NellcorSpO2
Measurement range: 1% ~ 100 %
Measurement accuracy: 70% ~ 100 %: ± 2 % (adult / pediatric)70 % ~ 100 %: ± 3 % (neonate)
0 % ~ 69 %: unspecified

Nellcor PR
Measurement range: 20 ~ 300 bpm;
Measurement accuracy: 20 ~ 250 bpm, ±3 bpm;
251 ~ 300 bpm: unspecified;
Upper limit of alarm: upper limit – 2 ~ 300 bpm;
Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm

MasimoSpO2
Measurement range: 1% ~ 100 %
Measurement accuracy:70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion)
70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion)
1 % ~ 69 %: unspecified

MasimoPR
Measurement range: 25 ~ 240 bpm
Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion)
Upper limit of alarm: upper limit – 2 ~ 240 bpm
Lower limit of alarm: 25bpm ~ lower limit + 2 bpm

TEMP
Channel: dual-channel
Measurement range: 0~ 50 ℃
Resolution: 1℃
Accuracy: ±1 ℃

CO2
Measurement mode: mainstream or sidestream
CO2measurement range: 0 ~ 150 mmHg
CO2resolution: 1 mmHg: 0 ~ 69 mmHg
0.25 mmHg: 70 ~ 150 mmHg
Accuracy:
0 ~ 40 mmHg: ± 2 mmHg
41 ~ 70 mmHg: ± 5 %
71 ~ 100 mmHg: ± 8 %
101 ~ 150 mmHg: ± 10 %
AwRRmeasurement range:
Sidestream: 2 ~ 120 rpm
Mainstream: 2 ~ 150 rpm
AwRRaccuracy: ± 1 rpm
Apnea alarm:yes
IBP
Channel: 4-channel
Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
Measurement and alarm range: -50~ 300 mmHg
Resolution: 1 mmHg
Accuracy: ±2 % or 1 mmHg, whichever is greater
Power supply: 100~ 240 V ~ 50/60 Hz
Safety class: class I, defibrillation-proof type CF applied part
Waterproof degree: IPX2

Physical characteristic:

Dimension: 47CM(L) × 25CM(W) × 44CM(H)
Weight: 15Kg

Package included:

1X AcuitSign TS15 multi-parameter Module Patient monitor

1X ECG cable: 5-lead, US or EU standard, TPU

1X SpO2 probe (integrated) Digital fingertip SpO2 probe for adult (CMS-N-SPO2 6P, 3M, yellow)

1X TEMP probe :R25=2.252K TEMP probe, skin surface type, CMS-N-TEMP 2P, PVC, L=3M

1X NIBP extension tube

1X Adult NIBP cuff (25 ~ 35 cm)

1X EtCO2 Module

1X IBP module

2XIBP cable

2XIBP sensor

1X Power Cable

1XUser manual

 

 

Reviews

There are no reviews yet.

Be the first to review “TS15 15.6 inch Touch Screen ICU CCU Module Patient Monitor 6 Parameters ECG SPO2 NIBP TEMP ETCO2 IBP”

Your email address will not be published. Required fields are marked *

Quick Navigation
Select your currency
$
GHS
×
×

Cart