Approved Handheld Vital Signs Monitor SINOHERO Portable Patient Multi Parameter 4.3” Inch Patient Monitor
GHS 8,771.60
9 in stock
Description
- Brand Name: LanYuXuan
- Type: Power Tool Parts
- Origin: CN(Origin)
- Place of Origin: China
- Brand Name: SINOHERO
- Model Number: XO
- Power Source: Electricity
- Warranty: 1 Year
- After-sale Service: Online technical support
- Material: Plastic, ABS
- Shelf Life: 1years
- Quality Certification: ce
- Instrument classification: Class II
- Safety standard: EN 149 -2001+A1-2009
- Product name: Patient Monitor
- Function: Detecting Body Health
- Feature: Testing Device
- Certificate: CE ISO
- Language version: 18 Languges Optional
- Color: Blue
- Display: 4.3″ TFT display
- Accuracy: 99.5%
- Memory: Memory Stores Minimum190000 Results
Lasting up to 8 hours with built-in battery and backup battery
Water-proof design equipped with first-aid bag and various carrying options to easily go anywhere
4.3″ Full-touch TFT-LCD display with multiple lay-outs
Various parameter configurations including Nellcor/Masimo SPO2, EtCO2 options
Size and Weight
– Size: 85mm(W)x190mm(L)x150mm(H)
– Weight: 1.2kg
Display
– 4.3″ color TFT Full Touch Screen
– Resolution: 480×272
Battery
– Type: Rechargeable Lithium battery
– Operating time under the normal use and full charge: > 120minutes
– Option backup battery will double operate time
Power supply
– Power Voltage: AC 100-240V 50/60Hz
– Safety Class: Category I
Input device
– Touch screen: Standard Configuration
Trend & Reviewing
– Trend: 48 hours
– NIBP measurement reviewing:1000 groups
Environment
– Operating temperature: +5℃ to +40℃
– Storage temperature:-20℃ to +50℃
– Operating humisity:15% to 85% (non condensing)
– Storage humidity :10% to 93% (non condensing)
– Operating atmospheric pressure:860hPa to 1060hPa
– Storage atmospheric pressure.500hPa to 1060hPa
ECG
– Lead type: 3-lead. 5-lead. 12-lead selectable
– ECG waveform: 2 channels
– Lead selection: 12-Lead I; II; Ill; aVR; aVL;aVF; V1-V6.
5-lead: I; Ill; aVR; aVL
3-lead: I; Ill
– Gain selection: x0.125; x0.25; x0.5; x1: x2; auto
– Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
– Heart rate range: Adult: 15-300bpm
Neonate/Pediatric: 15-350 bpm
– Accuracy: ±1bpm or ±1%, whichever is greater
– Resolution: 1 bpm
– Filter: ECG enlarge width: MON: 0.5-55Hz
DIA: 0.05-150Hz
OPE: 1-20Hz
– Alarm range: 15-350bpm
– ST segment detection: -2.0mV – +2.0Mv (Automatic)
– Arrhythmia analysis: Yes
– Pacemaker detection: detectable
RESP
– Method: impedance method
– Operation modes: Auto/ Manual
– Resolution: 1 rpm
– Measurement range: Adult: 0-120bpm
Neonate/Pediatric: 0-150bpm
– Alarm: Audible and visual alarm; alarm events recallable
– Sweep speed: 12.5mm/s; 25mm/s
– Gain selection: X0.25, X0.5, X1, X2
NIBP
– Method: Automatic Oscillometric
– Operation modes: Manual / Automatic / Continuous
– Measurement types: Systolic, Diastolic, Mean
– Range of systolic pressure: Adult mode 40-270mmHg
Pediatric mode 40-200mmHg
Neonatal mode 40-135mmHg
– Range of diastolic pressure: Adult mode 10-210mmHg
Pediatric mode 10-150mmHg
Neonatal mode 10-100mmHg
– Range of mean pressure: Adult mode 20-230mmHg
Pediatric mode 20-165mmHg
Neonatal mode 20-110mmHg
– Accuracy: Max mean error: 5mmHg
Max standard deviation: 8mmHg
– Resolution: 1mmHg
– Over-pressure protection: both Hardware and software
over pressure protection
Digital SpO2
Measurement & alarm range: 0-100%
– Resolution: 1%
– Accuracy: ±2% (70-100%, Adult/Pediatric, non-motion);
±3% (70-100%, Neonate, non-motion);
±3% (70-100%, Adult/Pediatric/Neonate, motion);
0-69% unspecified
– Alarm range: 1-100%
PR
– Range: 20-300bpm
– Resolution:1bpm
– Accuracy: ±3bpm(non-motion)
±5bpm(motion)
– Alarm range: 20-250bpm
Masimo SpO2
– Measurement & alarm range: 1-100%
– Resolution: 1%
– Measurement accuracy: ±2% (70-100%, Adult/Pediatric, non-motion);
±3% (70-100%, Neonate, non-motion);
±2% (70-100%, Adult/Pediatric/Neonate, motion);
Alarm range: 0-100%
PR
– Range: 25-240bpm
– Resolution:1bpm
– Accuracy: ±3bpm(non-motion)
±5bpm(motion)
– Alarm range:25-240bpm
Neilcor SpO2
– Measurement & alarm range: 0-100%
– Res lution: 1%
– Measurement accuracy:
±2% (70-100%, MAX-A, MAX-AL, MAX-N, MAX-P, MAX-I and MAX-FAST sensors)
±3% (70-100%, D-YS, DS-100A, OXI-NN and OXI-P/I sensors) 0-69% unspecified
PR
– Range: 20-300bpm
– Resolution: 1bpm
– Alarm range: 20-250bpm
TEMP
– Accuracy: ±0.1℃ (excluding the sensor)
– Measurement range: 0-50℃
– Channel: T1, T2, TD (temperature difference)
– Resolution: 0.1℃
EtCO2
– Range: 0-150mmHg
– Accuracy:±2% 0-40mmHg
±5% 41-70mmHg
±8% 71-100mmHg
±10% 101-150mmHg
– AwRR Accuracy: ±1rpm
– Convenient design for intubated and non-intubated applications
– Possible to work at low sample flow rate:50ml/min
Standard configuration of XO:
3/5 Lead ECG, SpO2, NIBP, RESP, HR/PR, 2-TEMP, Rechargeable Lithium Battery
Optional configuration of XO:
Nellcor SpO2, Masimo SpO2, 12 Lead ECG, Sidestream EtCO2, Microstream EtCO2 Waterproof First Aid Bag + Backup Battery
-
1 Sold
- -5%
- nurses breast watch
- Sold by: medecexpress
-
GHS 35.65
Super Deals - nurses breast watch
- Add to cart
-
0 Sold
- Larksci Laboratory 100-5000RPM 18tubes Centrifuge
- Sold by: medecexpress
-
GHS 6,782.24
Super Deals - Add to cart
-
0 Sold
- 4.5/6.5mm orthopedic trauma kit Large Fragment Instrument Set Surgical
- Sold by: medecexpress
-
GHS 320.00
Super Deals - Select options
-
0 Sold
- HF-410A Vein Finder Locator Handheld Portable
- Sold by: medecexpress
-
GHS 16,315.61
Super Deals - Add to cart
-
0 Sold
- Medical health Care Infrared Thermometer Baby Adult Ear oximeter Fingertip SPO2 Pulse
- Sold by: medecexpress
-
GHS 166.99 – GHS 176.99
Super Deals - Select options
-
0 Sold
- 1 pcs Stainless Steel Hemostatic Clamp Forceps
- Sold by: medecexpress
-
GHS 16.67 – GHS 31.62
Super Deals - Select options
Reviews
There are no reviews yet.